T6090 & T6091
Line Printer
Frequently Asked Questions

 
  Using Telnet With Lanplex 3
  Buffer Overflow
  Performing A Hex Dump
  Restoring Factory Defaults In The Printer
  Printing the Current Printer Configurations
  Printer Firmware Version
  Connecting Printer To AS400
  Setting Top Of Form
  Locking and Unlocking the Control Panel
  Printing Via External Print Server
  How Old Is The Printer?
  Set-Up Address Message
  Fourplex Connectors
  Paper Specifications
 
  Using Telnet With Lanplex 3
  If you try and communicate with the inbuilt network card via Telnet you will be asked for a login name and password. This is because the function is reserved for test use by the manufacturer. Telnet is NOT available for use by the user or system.
 
  Buffer Overflow
  If your printer displays the message "Buffer Overflow" in the Control Panel Display, you are most likely using the serial interface with Xon-Xoff protocol. This being the case, you need to make some particular settings in the serial interface parameters which are detailed in a technical note
 
  Performing A Hex Dump
  Switch the printer on and set to Offline and follow these instructions.
  • Press the Mode key: display will show Offline Normal.
  • Press any Arrow key until display shows Offline Config.
  • Press the Forms/1 key.
  • Press any Arrow key until display shows Config Printer.
  • Press the CPI/2 key.
  • Press any Arrow key until display shows Printer Dump Mode.
  • Press the LPI/3 key.
  • Press any Arrow key until display shows Dump Mode Style 1.
  • Press the Enter key and place printer Online.
  • Send Data to printer and data will be printed in hex format.

To return the printer to normal operation, either follow the above instructions, setting Dump Mode to Off or power cycle the printer.
 

  Restoring Factory Defaults In The Printer
  To restore the factory defaults within the printer, follow these instructions.
  • Press the Mode key: display will show Offline Normal.
  • Press any Arrow key until display shows Offline Config.
  • Press the Forms/1 key.
  • Press any Arrow key until display shows Config Printer.
  • Press the CPI/2 key.
  • Press any Arrow key until display shows Printer Load.
  • Press the LPI/3 key.
  • Press any Arrow key until display shows Load Default.
  • Press the Enter key and place printer Online.

Your printer is now set to the factory default configuration.
 

  Printing the Current Printer Configurations
  To print the current printer configurations, follow these instructions.
  • Press the Mode key: display will show Offline Normal.
  • Press any Arrow key until display shows Offline Config.
  • Press the Forms/1 key.
  • Press any Arrow key until display shows Config Printer.
  • Press the CPI/2 key.
  • Press any Arrow key until display shows Printer Report.
  • Press the LPI/3 key.
  • Press any Arrow key until display shows Report Configs.
  • Press the Enter key and the configurations will be printed.
  Printer Firmware Version
  To discover the printer firmware version print the Current Printer Configurations (see above) and look for the Main CPU Software version near the top of the printout.
 
  Connecting Printer To AS400
  The AS400 computers will not have a printer configuration for the Tally printers so if you are wanting a configuration for the printer, we recommend that you select the configuration for the Epson FX. You will also need to set the printer into the Epson emulation. 
 
  Setting Top Of Form
  To set the Top Of Form (TOF) follow these instructions:
  • Load paper into the top tractors.
  • Set the formlength in the Control Panel
  • Use the Arrow keys to move the paper until the position where you require the top row of dots to be is adjacent to the top of the tractor covers. Then press the TOF key on the control panel. This will cause the paper to move forward and be positioned at Top Of Form.
  Locking and Unlocking the Control Panel
  To Lock or Unlock the Control Panel, follow these instructions:
  • Set the printer to Offline.
  • Press the Enter and LF keys together for approx 3 - 4 seconds. The alarm will sound. (Tech Access On)
  • Press the Enter and CPI keys together for approx 3 - 4 seconds. The alarm will sound. (Panel Lock toggled)
  • Press the Enter and LF keys together for approx 3 - 4 seconds. The alarm will sound. (Tech Access Off)
  Printing Via External Print Server
  These printers are not reliable if connected to external print servers unless the printer parallel interface has been set Uni-Directional. To do this, you need to follow these instructions.
  • Set the printer to Offline.
  • Press the Enter and LF keys together for approx 3 - 4 seconds. The alarm will sound. (Tech Access On)
  • Press the Mode key: display will show Offline Normal.
  • Press any Arrow key until display shows Offline Config.
  • Press the Forms/1 key.
  • Press any Arrow key until display shows Config Paralel.
  • Press the CPI/2 key.
  • Press any Arrow key until display shows Paralel Bi-Dir.
  • Press the LPI/3 key.
  • Press any Arrow key until display shows Bi-Dir Off.
  • Press the Enter key and the interface will be set.
  • Press the Clear key.
  • Press the Enter and LF keys together for approx 3 - 4 seconds. The alarm will sound. (Tech Access Off)

On the external Print Server, you need to ensure that the unit is also set for Uni-directional working.
 

  Set-Up Address Message
  With a Fourplex controller board in the printer the "Setup Address" error message appears on power up when nothing is connected to the 15-way connector on the connector panel.

A simple solution to this is to install the CoAx plug in the 15-way connector which will cause the printer to believe it is a CoAx printer and the message will no longer be displayed. The CoAx plug was supplied with your printer. It is Part Number 080 306.
 

  Fourplex Connectors
 
Twinax Smart T cable - p/n 731529 Coax Connector - 080306
   
  Paper Specifications
 
Tractor Feed Paper Width 4" - 16",
Length 1-255 lines
One to six-part paper may be used with a maximum thickness of 0.025 inch. 15-100 lb. stock  (Reference specifications: ISO 2784, DIN 9771 and DIN 6721)